Applications

May be used as service-entrance conductors and in other applications where SE cables are permitted when installed as specified by NEC® Article 230. May be used in wet or dry locations at temperatures up to 90°C.

  • branch circuit wiring
  • feeders
  • service entrance
  • wet or dry locations
up arrow

Conductors

Stranded conductors:
  • Uncoated copper per ASTM-B3, ASTM-B8, and ASTM-B787
Phase Conductors:
  • Type THHN conductors
    Black PVC (polyvinyl chloride), rated to 90°C in wet or dry locations
    Jacketed with black nylon (polyamide)
    One phase conductor has a red stripe on its insulation surface for easy polarity identification
Neutral Conductor:
  • White PVC (polyvinyl chloride), rated 90°C
    Jacketed with white nylon (polyamide)
Equipment Ground Conductor:
  • Bare stranded copper conductor.
up arrow

Jacket

Gray, sunlight-resistant PVC (polyvinyl chloride) jacket over the complete assembly

up arrow

Industry Standards

UL 83 (insulated conductors)
UL 854 Service Entrance Cables, File No. 11098
ASTM-B3
ASTM-B8
ASTM-B787
Federal Specification A-A-59544
NFPA70: National Electrical Code®

up arrow

Assembly

Insulated and bare conductors are twisted together.
Glass-reinforced tape is applied over conductors.

up arrow

Surface Print

Sample: TYPE SE CABLE STYLE R TYPE THHN OR THWN CDRS 3 CDRS 6 AWG 1 CDR 6
AWG 600V E11098-A (UL)

up arrow

Lengths

  Package Code
  J
  500’ spool/reel
6-6-6-6 strand X
4-4-4-6 strand X
3-3-3-5 strand X
2-2-2-4 strand X
1-1-1-3 strand X
2/0-2/0-2/0-1 strand X

View Copper SER PDF for available lengths chart.

Where to Buy:

Please note NOT all products are sold in all locations. To confirm availability, please contact Customer Service.

up arrow

Product Specifications:

pdf iconView Printable PDF
    Stranding   Allowable Ampacities*    
Product Code Number
Explain Product Codes
Size/Construction AWG Phase Conductor & Neutral Equipment Grounding Conductor Aprox. O.D. Mils. 60°C** 75°C*** 90°C**** Approx. Net Wt. Lbs./M Ft.
136-3600J 6-6-6-6 7 7 660 55 65 75 - 411
136-4000J 4-4-4-6 7 7 800 70 85 95 100 595
136-4400J 3-3-3-5 7 7 905 85 100 110 110 738
136-4800J 2-2-2-2-4 7 7 970 95 115 130 125 899
136-5200J 1-1-1-3 19 7 1125 110 130 150 150 1140
136-6000J 2/0-2/0-2/0-1 19 19 1250 145 175 195 200 1772

If your product code is not listed above, please consult PDF or contact customer service.

*Per Table 310-16 NEC®
**For termination to equipment for circuits rated 100 amperes or less, or marked for size 14 through 1 AWG conductors.
See Art. 110.14 ©(1). NEC®.
***For termination to equipment for circuits rated over 100 amperes or marked for conductors larger than No. 1 AWG.
See Art. 110.14 ©(1) NEC®.
****Dry or wet locations, for ampacity derating purposes.
*****For dwelling units, conductors shall be permitted at listed ampacities for 120/240 volt, 3-wire, single-phase service conductors that supply the total load. Per Table 310-15(B)(6) NEC®.